  • Solvent Inlet Filters

    Thermo Scientific
    For HPLC Systems Stainless steel 10µm inlet filters for longer lifetime No tools required for replacement Bottom-of-the-Bottle solvent filters: Efficient draw 100% PTFE polymer, including 2µm filter Built-in helium sparge port and frit
  • Solvent Filters for G1311/12/54A Pumps

    Agilent Technologies
    Unfiltered solvents or solvents contaminated with microbial growth can clog solvent inlet filters, reducing the lifetime of the filter and impacting pump performance. Remember to clean or replace the solvent inlet filters at least once every 3 months.
  • Purge Valve

    Agilent Technologies
    Common to all 1100/1200 pump modules, the purge valve has a gold seal held in place with a plastic cup The most frequently replaced item in the 1100/1200 Series pumps is the purge valve PTFE frit, which can clog with seal material or solvent particulates When replacing the frit, remember that…
  • Injection Valve Maintenance

    Agilent Technologies
    Rotor seal replacement is the most common injection valve maintenance procedure.
  • GC/MSd Supplies

    Agilent Technologies
  • Seals And Pistons

    Agilent Technologies
    Pump seals should be replaced when there are leaks on the bottom of the pump head, when retention times are inconsistent, or when the pressure ripple is unstable. Each time the seals are replaced, the pistons (plungers) should be examined for scratches. Scratched pistons will cause small leaks…
  • Slipfeee Ferrules

    Thermo Scientific
    For use with SLIPFREE connectors for HPLC columns Vespel ferrules replace the standard Vespel ferrules supplied with SLIPFREE column connectors Kel-F and PEEK are offered for applications in which Vespel is not suitable
  • Upchurch PEEK Fingertight Fitting nut and ferrule 10-32

    Sigma-Aldrich
    Material: PEEK nut and ferrule Packaging: pkg of 10 ea I.D.:? 0.0625 in. (1.5875 mm) Fitting:? nut and ferrule 10-32 General description The one-piece fitting, 55067-U, is convenient to use because the ferrule will not stick in a receiving port and can be easliy found if…
  • Outlet Ball Valve

    Agilent Technologies
    Before exchanging the outlet ball valve, try cleaning it in a sonicator by placing the valve in an upright position (onto the plastic cap) in a small beaker with alcohol. Sonicate for 5 to 10 minutes. The 1100/1200 Series binary pump has a different outlet ball valve which includes a sieve.
  • Autosampler Kits

    Agilent Technologies
  • HPLC Detector Lamps

    Agilent Technologies
    Produced specifically to proprietary tolerances Reduced lamp-to-lamp variation Increased operating life Lamps for HPLC Detectors are produced using a new manufacturing process that results in more consistent operation characteristics. Lamps feature a more robust, more evenly…
  • Active Inlet Valve (AIV)

    Agilent Technologies
    The gold seal should be replaced after the valve has been removed a few times.