  • Purge Valve

    Agilent Technologies
    Common to all 1100/1200 pump modules, the purge valve has a gold seal held in place with a plastic cup The most frequently replaced item in the 1100/1200 Series pumps is the purge valve PTFE frit, which can clog with seal material or solvent particulates When replacing the frit, remember that…
  • Solvent Inlet Filters

    Thermo Scientific
    For HPLC Systems Stainless steel 10µm inlet filters for longer lifetime No tools required for replacement Bottom-of-the-Bottle solvent filters: Efficient draw 100% PTFE polymer, including 2µm filter Built-in helium sparge port and frit
  • Active Inlet Valve (AIV)

    Agilent Technologies
    The gold seal should be replaced after the valve has been removed a few times.
  • Diode Array Detector (DAD)/Multiple Wavelength Detector (MWD)

    Agilent Technologies
    Agilent's certified lamps are manufactured under ISO 9001 certified environment and are fully traceable through out every step of the production process. Each lamp is then tested to ensure it meets Agilent's specifications for performance. Test equipment is regularly calibrated using optical…
  • Autosampler Supplies

    Agilent Technologies
  • Seals And Pistons

    Agilent Technologies
    Pump seals should be replaced when there are leaks on the bottom of the pump head, when retention times are inconsistent, or when the pressure ripple is unstable. Each time the seals are replaced, the pistons (plungers) should be examined for scratches. Scratched pistons will cause small leaks…
  • Rheodyne Series 3725i

    Agilent Technologies
    Large sample volumes, high flow rates and preparative columns 100 ?l to 20 ml (10 ml loop installed) For biomolecules, the 3725i has PEEK materials
  • Rheodyne Series 7725i

    Agilent Technologies
    Stainless steel Most popular injection valve for analytical HPLC Loops range from 1 ?l to 5 ml (20 ?l loop installed) Built in position sensing switch provides the LC with reproducible start signal Selected as Agilent 1050 and 1100 manual injectors
  • HPLC Detector Lamps

    Agilent Technologies
    Produced specifically to proprietary tolerances Reduced lamp-to-lamp variation Increased operating life Lamps for HPLC Detectors are produced using a new manufacturing process that results in more consistent operation characteristics. Lamps feature a more robust, more evenly…
  • HPLC Reservoir, Conical Bottom, with Graduations

    Kimble
    Reservoir, Conical Bottom, Plastic-Coated, ULTRA-WARE® ULTRA-WARE Reservoirs have been specially designed for the preparation, storage and delivery of all liquid chromatography mobile phases. Each ULTRA-WARE Reservoir is manufactured from the most chemically inert glass available to prevent…
  • Peek Sample Loops

    Agilent Technologies
    Flexible PEEK loops have a clean, straight cut for low dead volume connections Inert to most organic solvents Wall thickness, temperature, exposure time and concentration of organic solvents affect the durability of PEEK tubing Concentrated nitric acid and sulfuric acid weaken PEEK…
  • Detector Lamps for Merck-Hitachi Instruments

    Thermo Scientific
    Low cost long-lasting deuterium lamps to fit most spectrophotometers and detectors. Thermo Brand Deuterium Lamps offer Best-in-Class spectral stability as well as superior lamp lifetime to insure that you get full value from each and every lamp. These lamps are engineered to be sure you get the…
  • Vacuum Degassers

    Agilent Technologies
    Maximum sensitivity in the low UV wavelength range High injection precision High retention time reproducibility Flow rates below 0.5 ml/min
  • Outlet Ball Valve

    Agilent Technologies
    Before exchanging the outlet ball valve, try cleaning it in a sonicator by placing the valve in an upright position (onto the plastic cap) in a small beaker with alcohol. Sonicate for 5 to 10 minutes. The 1100/1200 Series binary pump has a different outlet ball valve which includes a sieve.
  • 1100/1200 Needles and Needle Seats

    Agilent Technologies
    The needle should be replaced when it becomes bent, burred or blunt. The needle seat should be replaced when it is leaking or plugged. You should suspect a leak if you notice a trail of buffer crystals on the needle seat. The needle seat can become blocked if the sample contains particulates, as…
  • Thermostated Column Compartment

    Agilent Technologies
    Rotor seal replacement is the most common injection valve maintenance procedure.